Exadata Part II: Storage Index

Another important feature of the Exadata Database Machine that makes it more than just a collection of High-End Hardware are Storage Indexes. Storage Indexes are constructed automatically inside of the memory of the Storage Servers when Database segments (like heap tables) are being scanned. The Storage Cells are divided into 1 MB chunks and inside of these chunks, we record the minimum and maximum values of the columns of the table that allocated space inside that chunk. It is very well possible that these Storage Indexes make many of your „conventional indexes“ obsolete. Look at following drastic example:

SQL> connect adam/adam
Connected.
SQL> select bytes/1024/1024/1024 as gb from user_segments where segment_name='SALES';

 GB
----------
 1.5

This demonstration table was created with the following statement

SQL> create table sales as
select
rownum as id,
rownum + 1 as flag,
'Oracle Enterprise Edition' as product,
mod(rownum,5) as channel_id,
mod(rownum,1000) as cust_id ,
5000 as amount_sold,
trunc(sysdate - 10000 + mod(rownum,10000))
as order_date,
trunc(sysdate - 9999 + mod(rownum,10000))
as ship_date
from dual connect by level<=2e7;

I needed to put WORKAREA_SIZE_POLICY=MANUAL and I specified a SORT_AREA_SIZE=1048576000 to be able to do the connect by level<=2e7, by the way. That is because of the limitation of 200M pga memory for a single session when using PGA_AGGREGATE_TARGET. Anyway, please notice that id has unique values and there is no conventional index present.

SQL> set timing on
SQL> select * from sales where id=4711;

 ID       FLAG PRODUCT                   CHANNEL_ID    CUST_ID AMOUNT_SOLD ORDER_DAT SHIP_DATE
---------- ---------- ------------------------- ---------- ---------- ----------- --------- ---------
 4711       4712 Oracle Enterprise Edition          1        711        5000 28-JUL-96 29-JUL-96

Elapsed: 00:00:00.11

I have just scanned 1.5 Gigabyte of data in fractions of a second! [Previously said in 11 Milliseconds, but that was of course a mistake – apart from SQL*Plus not being able to produce that exact timing, I just got the unit wrong] That was possible, because the Storage Cells knew that they could exclude 1499 chunks from scanning. 4711 was only possibly present inside one of the chunks. Please notice that that was not a Smart Scan in the first place – we did not offload much I/O on the Storage Layer. Instead, we avoided I/O almost completely:

SQL> select name,value/1024/1024 as mb from v$statname natural join v$mystat
where name in
('cell physical IO interconnect bytes returned by smart scan',
'cell physical IO bytes saved by storage index');   2    3    4

NAME                                                                     MB
---------------------------------------------------------------- ----------
cell physical IO bytes saved by storage index                    1483.67969
cell physical IO interconnect bytes returned by smart scan       .001525879

To show the difference, I will do a Smart Scan. I connect again to initialize v$mystat

SQL> connect adam/adam
Connected.
SQL> select count(*) from sales where channel_id=1;

 COUNT(*)
----------
 4000000

Elapsed: 00:00:02.04
SQL> select name,value/1024/1024 as mb from v$statname natural join v$mystat
where name in
('cell physical IO interconnect bytes returned by smart scan',
'cell physical IO bytes saved by storage index');  2    3    4

NAME                                                                     MB
---------------------------------------------------------------- ----------
cell physical IO bytes saved by storage index                             0
cell physical IO interconnect bytes returned by smart scan       46.7903976

In this case, we scanned 1.5 Gig on the Storage Layer but delivered only 46 MB to the Database Layer. Now back to the Storage Index. Recently, I encountered the opinion that Storage Indexes would not work together with Bind Variables for some reason. That is not the case:

SQL> connect adam/adam
Connected.
SQL> vari n number
SQL> exec :n:=4711

PL/SQL procedure successfully completed.

SQL> set timing on
SQL> select * from sales where id=:n;

 ID       FLAG PRODUCT                   CHANNEL_ID    CUST_ID AMOUNT_SOLD ORDER_DAT SHIP_DATE
---------- ---------- ------------------------- ---------- ---------- ----------- --------- ---------
 4711       4712 Oracle Enterprise Edition          1        711        5000 28-JUL-96 29-JUL-96

Elapsed: 00:00:00.04
SQL>  select name,value/1024/1024 as mb from v$statname natural join v$mystat
where name in
('cell physical IO interconnect bytes returned by smart scan',
'cell physical IO bytes saved by storage index');  2    3    4

NAME                                                                     MB
---------------------------------------------------------------- ----------
cell physical IO bytes saved by storage index                    1483.67969
cell physical IO interconnect bytes returned by smart scan       .001525879

The Storage Index clearly could get used. Same with implicit datatype conversion:

SQL> vari c char(4)
SQL> exec :c:='4711'
SQL>  select * from sales where id=:c;

 ID       FLAG PRODUCT                   CHANNEL_ID    CUST_ID AMOUNT_SOLD ORDER_DAT SHIP_DATE
---------- ---------- ------------------------- ---------- ---------- ----------- --------- ---------
 4711       4712 Oracle Enterprise Edition          1        711        5000 28-JUL-96 29-JUL-96

Elapsed: 00:00:00.03
SQL>  select name,value/1024/1024 as mb from v$statname natural join v$mystat
where name in
('cell physical IO interconnect bytes returned by smart scan',
'cell physical IO bytes saved by storage index');  2    3    4

NAME                                                                     MB
---------------------------------------------------------------- ----------
cell physical IO bytes saved by storage index                    2967.35938
cell physical IO interconnect bytes returned by smart scan       .003051758

It would have surprised me a lot if Bind Variables would introduce any issues with Storage Indexes, because they are processed on the Database Layer. In fact, from the Optimizers viewpoint all these statements lead to the same execution plan: Full Table Scan. There could be an issue (but not exclusively related to Bind Variables), if we would have conventional indexes present here as well, because the Optimizer might favor them over the Storage Index. The Optimizer is not aware of Storage Indexes. Before I get another comment from Kevin suggesting to show joins with the example, let’s just do that:

SQL> select * from channels;

CHANNEL_ID CHANNEL_DESC
---------- ----------------------------------------
 0 Telesales
 1 Web
 2 Field
 3 Retail
 4 Promotion
 99 Special
SQL> create table customers as select distinct cust_id, 'John Doe' as cust_name from sales;

Table created.

Channels and Customers are now two dimension tables.

SQL> set timing on
SQL> select product,channel_desc,cust_name
from sales natural join channels
natural join customers
where id=4711;
 2    3    4
PRODUCT                   CHANNEL_DESC                             CUST_NAM
------------------------- ---------------------------------------- --------
Oracle Enterprise Edition Web                                      John Doe

Elapsed: 00:00:00.06
SQL> select name,value/1024/1024 as mb from v$statname natural join v$mystat
where name in
('cell physical IO interconnect bytes returned by smart scan',
'cell physical IO bytes saved by storage index');  2    3    4

NAME                                                                     MB
---------------------------------------------------------------- ----------
cell physical IO bytes saved by storage index                    1483.67969
cell physical IO interconnect bytes returned by smart scan       .001495361

Storage Indexes can obviously be used in this case as well. When we select on columns with non unique values, it depends on how well clustered the values are, whether it is beneficial to use a Storage Index. The values of order_date column of the sales table are spread across the whole table, which makes the usage of a Storage Index impossible to speed up the query:

SQL> connect adam/adam
Connected.
SQL> set timing on
SQL> select count(*) from sales where order_date=to_date('11.03.2009','dd.mm.yyyy');

 COUNT(*)
----------
 2000

Elapsed: 00:00:02.30
SQL> select name,value/1024/1024 as mb from v$statname natural join v$mystat
where name in
('cell physical IO interconnect bytes returned by smart scan',
'cell physical IO bytes saved by storage index');
 2    3    4
NAME                                                                     MB
---------------------------------------------------------------- ----------
cell physical IO bytes saved by storage index                             0
cell physical IO interconnect bytes returned by smart scan       .672538757

When we create the same table, but ordered by order_date, this changes:

SQL> create table sales_order as select * from sales where 1=2;
Table created.
SQL> alter table sales_order nologging;
Table altered.
SQL> insert /*+ append */ into sales_order select * from sales order by order_date;

20000000 rows created.
SQL> commit;

Commit complete.

Now we need to access the new table multiple times to get the Storage Index built:

SQL> connect adam/adam
Connected.
SQL>  select count(*) from sales_order where order_date=to_date('11.03.2009','dd.mm.yyyy');

 COUNT(*)
----------
 2000

Elapsed: 00:00:02.02
SQL>  select count(*) from sales_order where order_date=to_date('11.03.2009','dd.mm.yyyy');

 COUNT(*)
----------
 2000

Elapsed: 00:00:01.73
SQL>  select count(*) from sales_order where order_date=to_date('11.03.2009','dd.mm.yyyy');

 COUNT(*)
----------
 2000

Elapsed: 00:00:00.03
SQL> select name,value/1024/1024 as mb from v$statname natural join v$mystat
where name in
('cell physical IO interconnect bytes returned by smart scan',
'cell physical IO bytes saved by storage index');  2    3    4

NAME                                                                     MB
---------------------------------------------------------------- ----------
cell physical IO bytes saved by storage index                    1488.77344
cell physical IO interconnect bytes returned by smart scan       .506607056

Now the Storage has „learned“ that it is beneficial to have a Storage Index on the sales_order table. This index will be kept as long as the Cells are up. The Storage Index is created over all the table_columns, apparently. Please notice that I now access the column ship_date (strongly correlated to order_date) for the first time:

SQL> select count(*) from sales_order where ship_date=to_date('11.03.2009','dd.mm.yyyy');

 COUNT(*)
----------
 2000

Elapsed: 00:00:00.37
SQL> select name,value/1024/1024 as mb from v$statname natural join v$mystat
where name in
('cell physical IO interconnect bytes returned by smart scan',
'cell physical IO bytes saved by storage index');   2    3    4

NAME                                                                     MB
---------------------------------------------------------------- ----------
cell physical IO bytes saved by storage index                    2765.77344
cell physical IO interconnect bytes returned by smart scan       .562469482

Conclusion: Storage Indexes are another Smart Storage feature of Exadata Database Machine. They may make many conventional indexes obsolete. Although they are created and maintained automatically by the Storage Servers, it is important to know their behavior. Especially, it is relevant that (non unique) column values that we later on query for ocurr ordered to be able to benefit from Storage Indexes.

, ,

25 Kommentare

Exadata Part I: Smart Scan

As many of you will know, Oracle has introduced a new flagship in the core area: The Exadata Database Machine is a combined Hardware & Software offer, consisting of an 8 Node Cluster (each Node with 2 Six-Core CPUs and 72 GB RAM) and 14 Storage Servers (each with 2 Six-Core CPUs and 12 SAS or 12 SATA drives *) in case of a Full Rack, connected (RAC Interconnect & Storage) over Infiniband. Operating System is Oracle Enterprise Linux; Database Version is 11gR2 Enterprise Edition, both mandatory.

I have the privilege to get access to our Oracle University Database Machine – I really do love my job 🙂 But I am limited to only one Database Node with two Storage Servers – which explains the relatively slow speed during the demonstrations compared to a Full Rack.

The idea of this posting is to show that there is more behind the Exadata Database Machine than sophisticated and well combined Hardware, but that there is actually some kind of (Database) Intelligence built into the Storage Layer that enables it to do column & predicate filtering before it sends results to the Database Layer. This functionality is called Smart Scan:

SQL> create table sales as
select
'Oracle Enterprise Edition' as product,
mod(rownum,5) as channel_id,
mod(rownum,1000) as cust_id ,
5000 as amount_sold,
to_date
('01.' || lpad(to_char(mod(rownum,12)+1),2,'0') || '.2010' ,'dd.mm.yyyy')
as time_id
from dual connect by level<=2e7; 

Table created.
SQL> select bytes/1024/1024/1024 as gb from user_segments;

 GB
----------
 1.0625

Above created a roughly 1 Gig sized demo table that is now blown up to 4 Gig:

SQL> alter table sales nologging;

Table altered.

SQL> insert /*+ append */ into sales select * from sales;

20000000 rows created.

SQL> commit;

Commit complete.

SQL>  insert /*+ append */ into sales select * from sales;

40000000 rows created.

SQL> commit;

Commit complete.

SQL> select bytes/1024/1024/1024 as gb from user_segments;

 GB
----------
4.17822266

SQL> exec dbms_stats.gather_table_stats('ADAM','SALES')

PL/SQL procedure successfully completed.

The playing field is setup. We will look at first after the scan speed without Smart Scan:

SQL> alter session set cell_offload_processing=false;

Session altered.

SQL> set timing on
SQL> select /* NO_SMART_SCAN */ count(*) from sales where channel_id=1;

 COUNT(*)
----------
 16000000

Elapsed: 00:00:22.96
SQL> select /* NO_SMART_SCAN */ count(*) from sales where channel_id=1;

 COUNT(*)
----------
 16000000

Elapsed: 00:00:22.85
SQL> set timing off

Twice the statement to show that caching has not much to say in this situation. We needed about 23 seconds to scan about 4 Gig, with the Storage Servers delivering the full amount of data to the Database Layer. Now the very same statement with the standard functionality Smart Scan:

SQL>  alter session set cell_offload_processing=true;

Session altered.

SQL> set timing on
SQL> select /* WITH_SMART_SCAN */ count(*) from sales where channel_id=1;

 COUNT(*)
----------
 16000000

Elapsed: 00:00:05.58
SQL>  select /* WITH_SMART_SCAN */ count(*) from sales where channel_id=1;

 COUNT(*)
----------
 16000000

Elapsed: 00:00:05.64
SQL> set timing off

Runtime was reduced to less than 6 seconds with Smart Scan. Let’s examine the execution plans for the two statements. I included the comment (it is NOT a hint) to retrieve the statements and their execution plans easier from the Library Cache:

SQL> select sql_id from v$sql where sql_text like '%NO_SMART_SCAN%' and sql_text not like '%like%';

SQL_ID
-------------
81vy8y7fkvzta

SQL> select plan_table_output from table (dbms_xplan.display_cursor('81vy8y7fkvzta'));

PLAN_TABLE_OUTPUT
-------------------------------------
SQL_ID  81vy8y7fkvzta, child number 0
-------------------------------------
select /* NO_SMART_SCAN */ count(*) from sales where channel_id=1

Plan hash value: 1047182207

------------------------------------------------------------------------------------
| Id  | Operation                  | Name  | Rows  | Bytes | Cost (%CPU)| Time     |
------------------------------------------------------------------------------------
|   0 | SELECT STATEMENT           |       |       |       |   147K(100)|          |
|   1 |  SORT AGGREGATE            |       |     1 |     3 |            |          |
|*  2 |   TABLE ACCESS STORAGE FULL| SALES |    16M|    46M|   147K  (1)| 00:29:30 |
------------------------------------------------------------------------------------

Predicate Information (identified by operation id):
---------------------------------------------------

 2 - filter("CHANNEL_ID"=1)

An ordinary full table scan as expected. Now the second trial:

SQL> select sql_id from v$sql where sql_text like '%WITH_SMART_SCAN%' and sql_text not like '%like%';

SQL_ID
-------------
91w7a8mx8c977

SQL>  select plan_table_output from table (dbms_xplan.display_cursor('91w7a8mx8c977'));

PLAN_TABLE_OUTPUT
-------------------------------------
SQL_ID  91w7a8mx8c977, child number 0
-------------------------------------
 select /* WITH_SMART_SCAN */ count(*) from sales where channel_id=1

Plan hash value: 1047182207

------------------------------------------------------------------------------------
| Id  | Operation                  | Name  | Rows  | Bytes | Cost (%CPU)| Time     |
------------------------------------------------------------------------------------
|   0 | SELECT STATEMENT           |       |       |       |   147K(100)|          |
|   1 |  SORT AGGREGATE            |       |     1 |     3 |            |          |
|*  2 |   TABLE ACCESS STORAGE FULL| SALES |    16M|    46M|   147K  (1)| 00:29:30 |
------------------------------------------------------------------------------------

Predicate Information (identified by operation id):
---------------------------------------------------

 2 - storage("CHANNEL_ID"=1)
 filter("CHANNEL_ID"=1)

The Storage Layer did filter on the predicate channel_id=1 before transmitting the result to the Database Layer, which is the reason for the reduced runtime. Apart from Smart Scan, we have some more conventional ways to speed up the statement like doing it in parallel:

SQL> select /*+ parallel(sales) */ count(*) from sales where channel_id=1;

 COUNT(*)
----------
 16000000

Elapsed: 00:00:02.83
SQL> set timing off
SQL> select sql_id from v$sql where sql_text like '% parallel(sales) %' and sql_text not like '%like%';

SQL_ID
-------------
ckq93tnythxa7
QL> select plan_table_output from table (dbms_xplan.display_cursor('ckq93tnythxa7'));

PLAN_TABLE_OUTPUT
-------------------------------------
SQL_ID  ckq93tnythxa7, child number 0
-------------------------------------
select /*+ parallel(sales) */ count(*) from sales where channel_id=1

Plan hash value: 3130505568

------------------------------------------------------------------------------------------------------------------------
| Id  | Operation                      | Name     | Rows  | Bytes | Cost (%CPU)| Time     |    TQ  |IN-OUT| PQ Distrib |
------------------------------------------------------------------------------------------------------------------------
|   0 | SELECT STATEMENT               |          |       |       |  3409 (100)|          |        |      |            |
|   1 |  SORT AGGREGATE                |          |     1 |     3 |            |          |        |      |            |
|   2 |   PX COORDINATOR               |          |       |       |            |          |        |      |            |
|   3 |    PX SEND QC (RANDOM)         | :TQ10000 |     1 |     3 |            |          |  Q1,00 | P->S | QC (RAND)  |
|   4 |     SORT AGGREGATE             |          |     1 |     3 |            |          |  Q1,00 | PCWP |            |
|   5 |      PX BLOCK ITERATOR         |          |    16M|    46M|  3409   (1)| 00:00:01 |  Q1,00 | PCWC |            |
|*  6 |       TABLE ACCESS STORAGE FULL| SALES    |    16M|    46M|  3409   (1)| 00:00:01 |  Q1,00 | PCWP |            |
------------------------------------------------------------------------------------------------------------------------

Predicate Information (identified by operation id):
---------------------------------------------------

 6 - storage(:Z>=:Z AND :Z<=:Z AND "CHANNEL_ID"=1)
 filter("CHANNEL_ID"=1)

Parallel Query combined with Smart Scan was even faster, delivering

SQL> select 4.17/2.83 as GB_PER_SEC from dual;

GB_PER_SEC
----------
1.47349823

a scan rate of about 1.5 Gigabyte per Second. With an Oracle Database at hand, I don’t need a calculator 🙂

No idea what the weird storage filter :Z>=:Z and :Z<=:Z means here, to be honest.

Conclusion: Exadata is not only strong hardware but also Database intelligence on the storage layer. Smart Scan means the capability of the Storage Layer to do filtering of columns and predicates before sending the result to the Database Layer.

Addendum:

Using Enterprise Manager (Grid Control or  Database Control flavor even with Exadata), we have an easier way to determine Smart Scans:

* Second Addendum: Meanwhile (May 2011), also the High Capacity Drives are SAS – no more SATA

, ,

35 Kommentare